Tablet discolouration
This new bimonthly feature from CSMA, delves deeper into the world of surface analysis. The series will examine some of the most common problems facing professionals involved in the pharmaceutical industry, in both development and manufacturing, and will explore how these can be addressed (and often solved) using high-tech surface analysis techniques. The first surgery in the series looks at the problem of tablet discolouration.


Pharmaceutical Technology Europe



Figure 1 ToFSIMS spectra of drug samples.
We are currently experiencing a problem with one of our tablet lines. While the tablets appear white immediately after manufacture, after a time many of the tablets begin to take on a yellowish appearance. Could this be an issue that surface analysis could help resolve?

Discolouration issues present a very visible problem and can cost companies a great deal of money, regardless of whether the product (in this case a particular tablet formulation) itself is functionally affected or not.

But while the problem may be visible, the cause often isn't. The reason for this is that discolouration is almost always an issue that relates to surface conditions and not simply to bulk composition. Tiny variations in the outer nanometres of a particular tablet can be to blame for changes in appearance.

These variations are sometimes caused by contaminants that have penetrated the manufacturing process or, in other instances, by packaging treatments that lead to unforeseen chemical interactions. Occasionally, the chemical composition of the product surface reacts with the surrounding light and air, resulting in molecular conversion and possible changes in colouration.


Figure 2 Generation of secondary ions.
All three of these scenarios are very different, but, as the resulting effects are confined to the surface of the products, any attempt to troubleshoot a solution using bulk analysis is likely to prove inconclusive, as it will not have the required sensitivity to discern the chemistry of interest and relevance. With this in mind, surface analysis could not only help you and your company, but also be the only conclusive solution.

However, to say "surface analysis can help" is casting too broad a net, as there are numerous techniques encompassed by this description. For this particular product phenomenon I would initially recommend a programme of Time of Flight Secondary Ion Mass Spectrometry (ToFSIMS).

Other than its extreme analytical accuracy, the reason ToFSIMS is so suited to this scenario is that it is essentially nondestructive. As surface reactions could be the root of the discolouration, analysis techniques that alter or affect the sample's surface structure may also produce inaccurate data, or data that are true of lab conditions, but not manufacturing conditions. ToFSIMS provides an important and highly accurate troubleshooting solution.

So, which of the causes mentioned is the most likely scenario? It is impossible for me to say without access to the sample, but, given the time delay in the discolouration, I would favour some sort of reaction to light being the most likely cause. It is a more common issue than you might imagine, and one that we regularly see in the CSMA labs. A recent example of this may help to demonstrate.

A pharmaceutical sample submitted for ToFSIMS analysis displayed significant discolouration after manufacture. To assess the possible effects of light on the tablet formulation in question, a test was devised that analysed the following sample types:

  • Pristine drug reference (control sample).
  • Tablet prior to light exposure.
  • Tablet exposed to light (Figure 1).

In the tablet exposed to light, ToFSIMS showed that selective degradation of the drug molecule had taken place where the acetic acid group (—CH2COOH) was converted to an aldehyde group (—COH). This resulted in the formation of a new molecule (Mdeg) with a mass of 30 less than the pristine drug reference (Mdrug), where M=molecular mass. As a consequence of this conversion (the actual process is caused by the interaction between the carbonyl group (C=O) and the 'aromatic ring'), a shift in the light absorption from the ultraviolet region of the electromagnetic spectrum had taken place (at least partially) into the blue region of the visible spectrum. This results in an outward appearance of yellowish discolouration.


ADVERTISEMENT

LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
When sourcing raw materials and non-GMP intermediates or other chemicals, where are the majority of your suppliers located?
In the United States
In Western Europe
In Central and Eastern Europe
In Japan
In India
In China
In the United States
18%
In Western Europe
19%
In Central and Eastern Europe
3%
In Japan
2%
In India
31%
In China
28%
View Results
Jim MillerOutsourcing OutlookJim Miller Time for a Model Upgrade
Patricia Van ArnumIngredients InsiderPatricia Van Arnum Navigating the Global Pharmaceutical Supply Chain
Faiz kermaniSpotlightFaiz Kermani Reinvigorating European R&D innovation
Faiz kermaniStatistical Solutions Lynn Torbeck%RSD: Friend or Foe?
Life After Big Pharma
PhRMA Details Its Proposal for Internet and Social-Media Standards
The Unregulated Regulator
Rx-360 Goals Get off the Ground
US and Europe At Risk from Substandard Medicines
FindPharma Custom Search
Source: Pharmaceutical Technology Europe,
Click here